after attempt to break the 100G into 100x4 below logs and IM operation stuck RP/0/RP0/CPU0:ROUTER# sh im status br Fri Jun 9 19:20:55.229 GMT View: OWN - Owner, L3P - Local 3rd Party, G3P - Global 3rd Party, LDP - Local Data Plane GDP - Global Data Plane, RED - Redundancy, UL - UL Op: IFC - intf-create, IFD - intf-delete, CADD - caps-add, CREM - caps-remove BC - basecaps, CNSU - caps ns update, ATTR - attr-change, IDAT - init-data REPL - repl-ul-intf, REPL - repl-nodeid, REPL - repl-wildcard, SYNC - resync REG - registration, CFG - cfg-change, ACTV - act-virtual, LOOK - lookup OCHN - owner-channel, ISSU - issu-recreation, Clients that IM is waiting for. These clients may be preventing the completion of an in-progress operation and should be investigated further. |Node | JID | Process Name | Op | Wait time,s | FS | -----|--------------------|-----|--------------------|----|-------------|----| 1 0/0/CPU0 202 eth_intf_ma OCHN 143d 21h. ( jan 17 2023) Clients with IM operations in progress. These processes are expected to be blocked on IM until the operation can complete. The 'Waiting for' column references the table above. Node | JID | Process Name |Op | Wait time,s | Waiting for | --------------------|-----|--------------------|----|-------------|------------------------------------------------------------| 0/0/CPU0 334 fia_driver OCHN 143d 21h 1 Error
ID | Count | Description & First Instance | --------|-------|--------------------------------------------------------------------------------------------------------------| ops.01 1 Client with blocked ops Client fia_driver on node 0/0/CPU0 is waiting for client eth_intf_ma on node 0/0/CPU0 (flow id 0x001-fba3) Checking connections and node states.........OK Checking for unfinished operations.........FAIL Checking for trace errors....................OK ----------------------------------------------- Overall result.............................FAIL %PKT_INFRA-GIRO-4-GLOBAL_OPERATION_STALLED : Pending operation(s) (IM operation of type Interface Create) have retried unsuccessfully at least times over an extended period of time (last error: 'Subsystem(8191)' detected the 'unknown' condition 'Code(63)': Unknown error 494). This may indicate a non-transient issue that requires manual intervention to resolve. and %PLATFORM-VEEA-3-BCMDPA_L1_PORT_CREATION_FAILURE : bcmdpa l1 port create failed, ifname: HundredGigE0_0_0_29_1, unit:3 *Conditions:* run the commands: ! controller Optics0/0/0/29 breakout 4x100 over a Hundred Gig interface