Symptom
+ Forward drops on Spines matching CSCvd16972
+ These forward drops are of the type UC TENANT MYTEP BRIDGE MISS, ACL DROP, MC FIB MISS
+ These drops show up as Interface QoS Receive Error on NDI
Conditions
Ingress forward drops on Leafs Interface. These drops are of the type UC TENANT MYTEP BRIDGE MISS, ACL DROP, MC FIB MISS. These drops are reported as Interface QoS Receive Error to NDI. These drops are expected on ACI Leafs ref CSCvd16972
Workaround
None at this time
Further Problem Description
+module-1# show platform internal counters port 63
Stats for port 63
(note: forward drops includes sup redirected packets too)
IF LPort Input Output
Packets Bytes Packets Bytes
eth-1/63 63 Total 5096279444 1535767998505 5637788178 2296318266645
Unicast 5031426420 1512414417188 5637788180 2296318267135
Multicast 0 0 0 0
Flood 0 0 0 0
Total Drops 64851788 0
Storm Drops(bytes) 0
Buffer 0 0
Error 0 0
Forward 64851788
+ These drops are of the type: UC TENANT MYTEP BRIDGE MISS, ACL DROP, MC FIB MISS. i.e.
module-1# show plat internal hal 12 port gpd | egrep "Ss|1/63" (output shows S1=0, Ss=14)
module-1# show platform internal asic (output shows SliceSrc [0x14] : UC TENANT MYTEP BRIDGE MISS, ACL DROP, MC FIB MISS,)
+ These drops show up as Interface QoS Receive Error on NDI
+ Customer will like this Interface QoS Receive error due to sup redirected packets not be sent to NDI