Symptom
openconfig-components:transceiver/physical-channels streams dummy data for Optics even after the Optics is removed from the LC.
Conditions
1. NCS1004 with Line card and QSFP28 LR4 Optics inserted
2. Enable ON_CHANGE and SAMPLE GNMI subscription for openconfig-components:transceiver/physical-channels for PM monitoring
3. Remove the Optics
Workaround
No Workaround available for this.
Further Problem Description
When Optics is removed from the LC, expectation is that Delete notification is sent for Transceiver - each physical lane and No more data for the removed optics in the openconfig-components:transceiver/physical-channels. But currently delete notification is sent for a wrong component (optics_0_0_0_n instead of 0/0-optics0/0/0/n) and Dummy value is sent for 0/0-optics0/0/0/n as part of SAMPLE subscription for the removed optics