Symptom
After breaking the FMC HA, there is no LSP installed on the secondary FMC. Package exists on that FMC but it cannot to be reinstalled neither via GUI nor CLI.
Conditions
1. Break the HA
2. Primary FMC contains LSP but Secondary doesn't:
----------------[FMC-PRIMARY]-----------------
Model : Cisco Firepower Management Center 4600 (66) Version 7.0.5 (Build 72)
UUID : 11111111111111111111111111c
Rules update version : 2023-03-08-001-vrt
LSP version : lsp-rel-20230308-1550
VDB version : 361
----------------------------------------------------
----------------[FMC-SECONDARY]-----------------
Model : Cisco Firepower Management Center 4600 (66) Version 7.0.5 (Build 72)
UUID : 111122222222222222222222
Rules update version : 2023-03-08-001-vrt
VDB version : 361
----------------------------------------------------
3. Trial of reinstalling the LSP ends with the error:
/bin/sh: : No such file or directory
RC: 32512
The update failed!
Workaround
Upload and install a newer version of LSP using GUI.