Internal interface (nlp_int_tap) xlate entries are not getting displayed under show xlate after enabling ssh.
Enabled ssh 'any' (v4,v6) on inside_wm and pushed it to the device. Checked the nat table entries under NAT Section0. The following entries were created. firepower# sh nat Manual NAT Policies Implicit (Section 0) 1 (nlp_int_tap) to (inside_wm) source static nlp_server__ssh_0.0.0.0_intf2 interface destination static 0_0.0.0.0_4 0_0.0.0.0_4 service tcp ssh ssh translate_hits = 9, untranslate_hits = 18 2 (nlp_int_tap) to (outside_wm) source static nlp_server__ssh_0.0.0.0_intf4 interface destination static 0_0.0.0.0_6 0_0.0.0.0_6 service tcp ssh ssh translate_hits = 0, untranslate_hits = 0 3 (nlp_int_tap) to (inside_wm) source static nlp_server__ssh_::_intf2 interface ipv6 destination static 0_::_5 0_::_5 service tcp ssh ssh translate_hits = 3, untranslate_hits = 13 4 (nlp_int_tap) to (outside_wm) source static nlp_server__ssh_::_intf4 interface ipv6 destination static 0_::_7 0_::_7 service tcp ssh ssh translate_hits = 0, untranslate_hits = 0 4. show xlates does not show the xlates for the internal interface nlp_int_tap. firepower# sh xlate 9 in use, 10 most used Flags: D - DNS, e - extended, I - identity, i - dynamic, r - portmap, s - static, T - twice, N - net-to-net firepower#