Symptom
Devices that do not operate in platform mode may have health monitoring alerts on the FMC as though they are operating in platform mode.
The device shows the following in the FXOS troubleshoot:
*********************************************************************
fxos-mode, cc-mode, fips-mode
*********************************************************************
`scope security`
`show fxos-mode`
Mode is currently set to platform
Conditions
Seen with FTD/FMC on 7.0.1 after an upgrade from 6.6.4.
Further Problem Description
Errors similar to the below may be seen on FTD and pushed to FMC:
*************************** 31. row ***************************
description: 1 Critical EventsCode - F1000293; Occurrence - 1; Time - 2022-08-17T13.20.35.543; Description - [FSM.FAILED]. realm configuration(FSM.sam.dme.AaaRealmUpdateRealm)
status: red
*************************** 32. row ***************************
description: 1 Major EventsCode - F1329; Occurrence - 1; Time - 2022-09-01T12.07.31.983; Description - Ntp Configuration failed, please check the error message in Ntp host
status: red
*************************** 33. row ***************************
description: 2 Warning EventsCode - F17253; Occurrence - 3; Time - 2022-08-17T13.05.05.417; Description - [FSM.STAGE.FAILED]. realm configuration to primary(FSM-STAGE.sam.dme.AaaRealmUpdateRealm.SetRealmLocal)Code - F78693; Occurrence - 1; Time - 2022-08-17T13.20.35.542; Description - [FSM.STAGE.REMOTE-ERROR]. Result. failure Code. ERR-aaa-config-modify-error Message. Failed to execute command. /opt/ssp-mgmt-scripts/fxos_apply_aaa_config.sh /etc/ldap.yaml, Error code. 3 (sam.dme.AaaRealmUpdateRealm.SetRealmLocal)
status: yellow