Symptom
When the following command is run with "active" keyword and the interface is located in the standby switch, will show the following error:
Device#sh platform hardware fed switch active qos queue config interface
Interface not found, err 18
The same happens when using "standby" keyword and the interface is located in the active switch. This is a request
Conditions
Pair of Catalyst 9500 running StackWise Virtual
Workaround
None - This is an expected behavior
Further Problem Description
This is an enhancement request to have a more explanatory error message, something like:
Interface is not located in the active switch, try using "standby" keyword