Symptom
C8300 router showing flow-control as OFF when connected to C9300 port which supports flow-control only in input direction.
GigabitEthernet0/0/3 is up, line protocol is up
Hardware is 4x1G-2xSFP, address is c0f8.7f31.25a3 (bia c0f8.7f31.25a3)
Description: Office LAN To CR01:Tw1/0/1 - interconnect VRF0 (global) to VRF100 (CORP)
Internet address is 10.65.188.121/30
MTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation 802.1Q Virtual LAN, Vlan ID 1., loopback not set
Keepalive not supported
Full Duplex, 1000Mbps, link type is auto, media type is RJ45
output flow-control is off, input flow-control is off
Conditions
- The issue is seen when neighbor node supports flow-control only in input direction.
- The issue is seen when autonegotiate is configured. With manual settings the flow-control shows ON.
Workaround
Use manual speed and duplex settings.