...
We can check these statistics using the below command sh controllers fh0/3/0/8 xgxs /mac /all >>>>>>>> the output is the real time data Fri Oct 14 16:25:57.548 AEDT fec_type FEC_KP4 FEC_KP4 Serdes Pin Defects: Port Defects: PHY channelized defects: dfec_deg_ser i:0 v:0 e:0 i:0 v:0 e:0 rx_rsfec_corr_cw i:1 v:0 e:0 i:0 v:0 e:0 rx_rsfec_uncorr_cw i:0 v:0 e:1 i:0 v:0 e:1 rx_fcfec_corr_cw i:0 v:0 e:1 i:0 v:0 e:1 rx_fcfec_uncorr_cw i:0 v:0 e:1 i:0 v:0 e:1 MAC channelized defects: PB channel defects: Ethernet Flow Control Defects: TX defects: RX defects: sdlane_fec_symb_err_cnt 8072 0 sdlane_fec_symb_err_cnt 9903 0 sdlane_fec_symb_err_cnt 81138 0 sdlane_fec_symb_err_cnt 68260 0 sdlane_fec_symb_err_cnt 1020 0 sdlane_fec_symb_err_cnt 506 0 sdlane_fec_symb_err_cnt 25050 0 sdlane_fec_symb_err_cnt 19595 0 sdlane_fec_symb_err_cnt 1313 0 sdlane_fec_symb_err_cnt 2321 0 sdlane_fec_symb_err_cnt 72875 0 sdlane_fec_symb_err_cnt 122510 0 sdlane_fec_symb_err_cnt 2702 0 sdlane_fec_symb_err_cnt 2534 0 sdlane_fec_symb_err_cnt 29015 0 sdlane_fec_symb_err_cnt 32809 0 fec_corr_err_cnt 479520 0 fec_uncorr_err_cnt 0 0 fec_symb_err_cnt 479623 0 rsfec_enabled : TRUE rsfec_aligned : TRUE rsfec_cor_block_errors : 0 rsfec_uncor_block_errors : 8 rsfec_ecc_errors : 0 fcfec_enabled : FALSE BUT ON CISCO 8000 ROUTER : the FEC statistics looks like the below , this is the accumulated statistics on this interface RP/0/RP0/CPU0:bar-core30.prodsup#sh controllers FH0/0/0/3 Alarm Alarm Warning Warning Alarm Thresholds High High Low Low ------- ------- ------- ------- Transceiver Temp (C): 80.000 75.000 0.000 -5.000 Transceiver Voltage (V): 3.630 3.465 3.135 2.970 Laser Bias (mA): 65.000 60.000 35.000 30.000 Transmit Power (mW): 6.456 3.388 0.524 0.208 Transmit Power (dBm): 8.100 5.299 -2.807 -6.819 Receive Power (mW): 6.456 3.388 0.123 0.048 Receive Power (dBm): 8.100 5.299 -9.101 -13.188 Statistics: FEC: Corrected Codeword Count: 16475268629 Uncorrected Codeword Count: 84 Forward error correction: Standard (Reed-Solomon)
We can check these statistics using the below command sh controllers fh0/3/0/8 xgxs /mac /all >>>>>>>> the output is the real time data Fri Oct 14 16:25:57.548 AEDT fec_type FEC_KP4 FEC_KP4 Serdes Pin Defects: Port Defects: PHY channelized defects: dfec_deg_ser i:0 v:0 e:0 i:0 v:0 e:0 rx_rsfec_corr_cw i:1 v:0 e:0 i:0 v:0 e:0 rx_rsfec_uncorr_cw i:0 v:0 e:1 i:0 v:0 e:1 rx_fcfec_corr_cw i:0 v:0 e:1 i:0 v:0 e:1 rx_fcfec_uncorr_cw i:0 v:0 e:1 i:0 v:0 e:1 MAC channelized defects: PB channel defects: Ethernet Flow Control Defects: TX defects: RX defects: sdlane_fec_symb_err_cnt 8072 0 sdlane_fec_symb_err_cnt 9903 0 sdlane_fec_symb_err_cnt 81138 0 sdlane_fec_symb_err_cnt 68260 0 sdlane_fec_symb_err_cnt 1020 0 sdlane_fec_symb_err_cnt 506 0 sdlane_fec_symb_err_cnt 25050 0 sdlane_fec_symb_err_cnt 19595 0 sdlane_fec_symb_err_cnt 1313 0 sdlane_fec_symb_err_cnt 2321 0 sdlane_fec_symb_err_cnt 72875 0 sdlane_fec_symb_err_cnt 122510 0 sdlane_fec_symb_err_cnt 2702 0 sdlane_fec_symb_err_cnt 2534 0 sdlane_fec_symb_err_cnt 29015 0 sdlane_fec_symb_err_cnt 32809 0 fec_corr_err_cnt 479520 0 fec_uncorr_err_cnt 0 0 fec_symb_err_cnt 479623 0 rsfec_enabled : TRUE rsfec_aligned : TRUE rsfec_cor_block_errors : 0 rsfec_uncor_block_errors : 8 rsfec_ecc_errors : 0 fcfec_enabled : FALSE BUT ON CISCO 8000 ROUTER : the FEC statistics looks like the below , this is the accumulated statistics on this interface RP/0/RP0/CPU0:bar-core30.prodsup#sh controllers FH0/0/0/3 Alarm Alarm Warning Warning Alarm Thresholds High High Low Low ------- ------- ------- ------- Transceiver Temp (C): 80.000 75.000 0.000 -5.000 Transceiver Voltage (V): 3.630 3.465 3.135 2.970 Laser Bias (mA): 65.000 60.000 35.000 30.000 Transmit Power (mW): 6.456 3.388 0.524 0.208 Transmit Power (dBm): 8.100 5.299 -2.807 -6.819 Receive Power (mW): 6.456 3.388 0.123 0.048 Receive Power (dBm): 8.100 5.299 -9.101 -13.188 Statistics: FEC: Corrected Codeword Count: 16475268629 Uncorrected Codeword Count: 84 Forward error correction: Standard (Reed-Solomon) OBSERVATION : The FEC data on ASR9K is real time data and not accumulated data But on the cisco 8000 the FEC data is accumulated data REQUIREMENT : On the ASR9K is there any command that can provided the accumulated FEC statistics as the current command provides only the real time data The customer need the accumulated data that is seen similar in 8000 , if the current version does not support it , in the future is there a possibility this option can be included REASON FOR THIS REQUIREMENT : based on this troubleshooting and health of the link will be determined
NA