Symptom
A vulnerabilty in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system of an affected device.
This vulnerability is due to insufficient validation of user-supplied files in the configuration import feature. An attacker could exploit this vulnerability by uploading a crafted SFO file to an affected device. A successful exploit could allow the attacker to execute arbitrary commands on the underlaying operating system as the 'www' user.
In order to exploit this vulnerability, the attacker would need to have administrative credentials on the web interface of FMC
Conditions
Device running in default configuration
Workaround
There are no workarounds that address this issue
Further Problem Description
None
PSIRT Evaluation
The Cisco PSIRT has assigned this bug the following CVSS version 3.1 score. The Base CVSS score as of the time of evaluation is 2.7:
https://tools.cisco.com/security/center/cvssCalculator.x?vector=CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L
No CVE ID has been assigned to this issue.
Information about Fixed, Vulnerable, and Nonvulnerable releases--as well as information about fixed release availability--is not maintained by Cisco PSIRT. Please refer to the appropriate fields in this bug. If you require additional help to obtain this information, please open a support case with your support organization.
Additional information on Cisco's security vulnerability policy can be found at the following URL:
https://tools.cisco.com/security/center/resources/security_vulnerability_policy.html