Symptom
Take one port on the 20HG-PEC card, Hu0/0/1/5.
We can see two entities for the same port
iso.3.6.1.2.1.47.1.1.1.1.7.10003 = STRING: "0/0-SFP+ bay 41"
iso.3.6.1.2.1.47.1.1.1.1.7.10033 = STRING: "0/0-QSFP bay 41 / SFP+ bay 61"
There is optics inserted in the port
iso.3.6.1.2.1.47.1.1.1.1.7.3788801 = STRING: "HundredGigE0/0/1/5"
If we check the ContainedIn OID for this optics
iso.3.6.1.2.1.47.1.1.1.1.4.3788801 = INTEGER: 10003 <<<< It is pointing to incorrect index 10003 which is the SFP+ bay as we can see above instead of index 10033 which is the correct QSFP bay
Conditions
ASR9903 with ASR9903-20HG-PEC card