Symptom
On executing SNMP Walk on Lane data of Optics controllers, after fresh setup boot up, OID's related to lane data are not returning values.
NCS540-X SNMP walk failed 1.3.6.1.4.1.9.9.828.1.1.3.1.2, 1.3.6.1.4.1.9.9.828.1.1.3.1.3
>snmpwalk -v2c -c public 1.3.6.1.4.1.9.9.828.1.1.3.1.2
SNMPv2-SMI::enterprises.9.9.828.1.1.3.1.2 = No Such Instance currently exists at this OID
>snmpwalk -v2c -c public 1.3.6.1.4.1.9.9.828.1.1.3.1.3
SNMPv2-SMI::enterprises.9.9.828.1.1.3.1.3 = No Such Instance currently exists at this OID
Conditions
It observed when do SNMP walk on lane data of optics controller on NCS540-AARCH64
1.3.6.1.4.1.9.9.828.1.1.3.1.2
1.3.6.1.4.1.9.9.828.1.1.3.1.3
Workaround
Users need to perform, process restart (either of one applicable process name).