Symptom
Telemetry failing to stream Cisco-IOS-XR-asr9k-fsi-oper:fabric-stats/nodes/node/statses/stats
RP/0/RP1/CPU0:ASR-9912-B#show telemetry model-driven subscription TEST internal
Thu Aug 4 19:44:09.733 JST
Subscription: TEST
-------------
State: ACTIVE
Source Interface: MgmtEth0_RP0_CPU0_0(Up 0x60000000)
Sensor groups:
Id: TEST
Id: 14
Sample Interval: 60000 ms (strict-timer)
Heartbeat Interval: NA
Heartbeat always: False
Encoding: self-describing-gpb
Num of collection: 1
Collection time: Min: 0 ms Max: 0 ms
Total time: Min: 3 ms Avg: 3 ms Max: 3 ms
Total Deferred: 0
Total Send Errors: 0
Total Send Drops: 0
Total Other Errors: 0
No data Instances: 1
Last Collection Start:2022-08-04 19:43:47.104702403 +0900
Last Collection End: 2022-08-04 19:43:47.104705403 +0900
Sensor Path: Cisco-IOS-XR-asr9k-fsi-oper:fabric-stats/nodes/node/statses/stats/counter-names/counter-name/counter
Sysdb Path: /oper/controller-fsi-xml/gl/node/*/fsi/*/counterlist/*/counter
Count: 1 Method: FINDDATA Min: 0 ms Avg: 0 ms Max: 0 ms
Item Count: 0 Status: Active
Missed Collections:0 send bytes: 0 packets: 0 dropped bytes: 0 <<<<<
Id: 15
/snip/
Sensor Path: Cisco-IOS-XR-asr9k-fsi-oper:fabric-stats/nodes/node/statses/stats/stats-array
Sysdb Path: /oper/controller-fsi-xml/gl/node/*/fsi/*/statsarray
Count: 1 Method: FINDDATA Min: 0 ms Avg: 0 ms Max: 0 ms
Item Count: 0 Status: Active
Missed Collections:0 send bytes: 0 packets: 0 dropped bytes: 0 <<<<<
Conditions
occurs after RP Switchover