Symptom
Device CLI ( IOS XE) , is allowing to configure bandwidth remaining ratio value from 1-65536. However, as per the documents the Ratio Value should be between 1 - 1000.
HUB(config-pmap-c)# bandwidth remaining ratio ?
Ratio
Once this is configured above the threshold ie.,1000, following logs generated by the system and policy will failed to gets installed.
%NHRP-3-QOS_POLICY_APPLY_FAILED: Failed to apply QoS policy spoke-5000Mbps-parent mapped to NHRP group spoke-5000Mbps on interface Tunnel100, to tunnel x.x.x.x due to policy installation failure
bandwidth remaining ratio must be between 1 and 1000 for this interface
Conditions
The issue is seen once the IOS XE platforms
Workaround
Limit the value of bandwidth remaining ratio between 1-1000 in order to have policy installed