Symptom
When selecting the "deploy" page, only following is seen:
Error while fetching data. Details ("message": "validation failed", "errors":
["keyword": "required" "dataPath":" deviceStatusList|O]","schemaPath":"#/required" "params":
{"missing Property": "domain"), "message":"should have required property 'domain''}],"validation":true,"ajv":true}
Further investigation will show that the number of "active: 1" sensors for the sensor table in both sybase and mysql differ, with sybase sensor table containing fewer "active: 1" sensors.
Conditions
After registering a new sensor the deployment page is not available due to the broken sync between the two databases.
Workaround
Contact TAC for workaround.