Symptom
After upgrade from 7.2.2 to 7.3.2, some ports using QSFP-4X10G-LR-S optics on NC55-MOD-A-SE-S Linecards remain down.
Fia_driver process reports the below log continually for these ports on the affected LC.
LC/0/1/CPU0:Feb 15 13:14:10.588 CET: fia_driver[245]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/1/0/13/0, Detected Local Fault
LC/0/1/CPU0:Feb 15 13:14:10.775 CET: fia_driver[245]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/1/0/13/0, Detected Local Fault
LC/0/1/CPU0:Feb 15 13:14:11.264 CET: fia_driver[245]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/1/0/13/2, Detected Local Fault
LC/0/1/CPU0:Feb 15 13:14:12.884 CET: fia_driver[245]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/1/0/13/0, Detected Local Fault
LC/0/1/CPU0:Feb 15 13:14:13.063 CET: fia_driver[245]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/1/0/13/0, Detected Local Fault
Issue does not happen when same optics are inserted on NC55-36X100G-A-SE Linercard.
Conditions
Upgrade to 7.3.2.
This problem has been observed on optics QSFP-4X10G-LR-S from vendor "CISCO-FO" and vendor "CISCO-Skylane".
Issue was not replicated on LAB when using "CISCO-INNOLIGHT" optics and "CISCO-CISCO" optics.