Symptom
1. ISE services don't come up. The ISE command line interface (CLI) command "application start ise" shows the following error.
#application start ise
% Error: ISE Integrity Check Failed! One or more ISE program files appears to
% be tampered with. Check system log for specific error(s).
% Application failed to start
2. Running the command line interface (CLI) "show logging system ade/ADE.log | include Integritycheck" shows
2022-06-07T22:25:32.455041+00:00 sec-test-18 ADE-SERVICE[1372]: [1108343]:[info] application:operation cars_install.c[5165] [system]: Verified signature of integritycheck program with abraxas release key
2022-06-07T22:25:44.793540+00:00 sec-test-18 ADE-SERVICE[1372]: [1108343]:[info] application:operation cars_install.c[5233] [system]: Integritycheck returned: 1 with output: Verified signature of integritycheck.sums file with Swims release key #012/opt/CSCOcpm/appsrv/apache-tomcat-9.0.54/webapps/admin/WEB-INF/classes/buildType.properties: FAILED#012integritycheck: WARNING: 1 line is improperly formatted#012integritycheck: WARNING: 1 computed checksum did NOT match
2022-06-07T22:25:44.793824+00:00 sec-test-18 ADE-SERVICE[1372]: [1108343]:[error] application:operation cars_install.c[5238] [system]: Integritycheck Failed!
Conditions
The ISE Administration web application Enable TAC Support was disabled by unchecking the "TAC Support Cases" checkbox.
Menu: Administration > System > Settings
Left-Side Navigation: Enable TAC Support Cases
Workaround
rollback patch 3 or install p4
Further Problem Description