Symptom
A vulnerability in the management web server of Cisco Firepower Threat Defense (FTD) Software could allow an authenticated, remote attacker with high privileges to execute configuration commands on an affected system.
This vulnerability exists because access to HTTPS endpoints is not properly restricted on an affected device. An attacker could exploit this vulnerability by sending specific messages to the affected HTTPS handler. A successful exploit could allow the attacker to perform configuration changes on the affected system, which should be configured and managed only through Cisco Firepower Management Center (FMC) Software.
Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.
This advisory is available at the following link:
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-ftd-mgmt-privesc-7GqR2th
The Cisco Product Security Incident Response Team (PSIRT) validates only the affected and fixed release information that is documented in this advisory.
Conditions
Please refer to the Security Advisory.
Workaround
Please refer to the Security Advisory.
Further Problem Description
Please refer to the Security Advisory.
PSIRT Evaluation
The Cisco PSIRT has assigned this bug the following CVSS version 3 score. The Base CVSS score as of the time of evaluation is 6.5:
https://tools.cisco.com/security/center/cvssCalculator.x?vector=CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
CVE ID CVE-2022-20949 has been assigned to document this issue.
Information about Fixed, Vulnerable, and Nonvulnerable releases--as well as information about fixed release availability--is not maintained by Cisco PSIRT. Please refer to the appropriate fields in this bug. If you require additional help to obtain this information, please open a support case with your support organization.