Symptom
Config is lost on reimage, despite use of "preserve config" flag.
Conditions
Performing a reimage from 7.2.x->7.3.2 on NCS540L
To check if the device is affected. It must be an NCS540L device running 7.2.x. Then execute:
cat /sys/bus/mmc/devices/mmc0:0001/name
If the result is HBG4a2, then the device is affected.
Further Problem Description
This issue only impacts users going from 7.2.x->7.3.2 (via reimage) on a subset of NCS540L devices.
Other NCS540L devices, other releases, and other platforms are not impacted.