Symptom
The data displayed when executing the show controller phy | inc dBm is accurate.
show controller hu1/7/0/19 phy | beg Tx bias
Thu Feb 10 18:56:47.749 UTC
Tx bias: 149.57 mA
Total Tx power: 6.83 mW ( 8.34 dBm)
Lane 0 Tx power: 1.73 mW ( 2.38 dBm)
Lane 1 Tx power: 1.68 mW ( 2.26 dBm)
Lane 2 Tx power: 1.52 mW ( 1.82 dBm)
Lane 3 Tx power: 1.90 mW ( 2.78 dBm)
Total Rx power: 1.91 mW ( 2.82 dBm)
Lane 0 Rx power: 0.48 mW ( -3.16 dBm)
Lane 1 Rx power: 0.46 mW ( -3.34 dBm)
Lane 2 Rx power: 0.47 mW ( -3.23 dBm)
Lane 3 Rx power: 0.49 mW ( -3.06 dBm)
SNMP Poll for the Corresponding Optical Sensor OID displays inaccurate values
.1.3.6.1.2.1.47.1.1.1.1.7.13218061 = STRING: "1/7-PORT-19-Tx Lane 0 Power"
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.13218061 = INTEGER: 0
.1.3.6.1.2.1.47.1.1.1.1.7.13218062 = STRING: "1/7-PORT-19-Tx Lane 1 Power"
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.13218062 = INTEGER: 1962
.1.3.6.1.2.1.47.1.1.1.1.7.13218063 = STRING: "1/7-PORT-19-Tx Lane 2 Power"
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.13218063 = INTEGER: 1701
.1.3.6.1.2.1.47.1.1.1.1.7.13218064 = STRING: "1/7-PORT-19-Tx Lane 3 Power"
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.13218064 = INTEGER: 1944
.1.3.6.1.2.1.47.1.1.1.1.7.13218073 = STRING: "1/7-PORT-19-Rx Lane 0 Power"
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.13218073 = INTEGER: 0
.1.3.6.1.2.1.47.1.1.1.1.7.13218074 = STRING: "1/7-PORT-19-Rx Lane 1 Power"
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.13218074 = INTEGER: 385
.1.3.6.1.2.1.47.1.1.1.1.7.13218075 = STRING: "1/7-PORT-19-Rx Lane 2 Power"
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.13218075 = INTEGER: 366
.1.3.6.1.2.1.47.1.1.1.1.7.13218076 = STRING: "1/7-PORT-19-Rx Lane 3 Power"
.1.3.6.1.4.1.9.9.91.1.1.1.1.4.13218076 = INTEGER: 410
Conditions
Issue is seen in HuGige interfaces.
Workaround
None
Recovery Process:
Process restart of slice_manager on the affected line card from the Sysadmin VM --> "process restart slice_manager loc " clears the issue.
Further Problem Description
The slice_manager will update the sensor data when one of the following events occurs:
- Process restart of slice_manager on the affected LC.
- LC Reload
- Optical Cable Pull/Insert
- Optics OIR
- Level change of > +/- 50 uW from previous reading. The slice_manager process checks for a change in the level every minute and will update if current value it is +/- 50 uW of the previous reading.