End devices can't establish FCNS sessions with NPIV switches after successfully FLOGI'ing into the upstream NPIV switch. FCNS repsonses from the upstream switch are not recorded on the N9K `show npv internal event-history ext-if-fsm` 488) FSM: Transition at 653326 usecs after Wed Nov 17 20:57:36 2021 Previous state: [NPIVP_EXT_IF_ST_WAITING_FLOGI_RESPONSE] <<<< Waiting for FLOGI response Triggered event: [NPIVP_EXT_IF_EV_INT_FLOGI_RESPONSE] Next state: [FSM_ST_NO_CHANGE] 489) FSM: Transition at 653352 usecs after Wed Nov 17 20:57:36 2021 Previous state: [NPIVP_EXT_IF_ST_WAITING_FLOGI_RESPONSE] Triggered event: [NPIVP_EXT_IF_EV_INT_FLOGI_RESPONSE_SUCCESS] <<<< FLOGI response OK Next state: [NPIVP_EXT_IF_ST_WAITING_LC_PORT_CONFIG] 490) FSM: Transition at 653364 usecs after Wed Nov 17 20:57:36 2021 Previous state: [NPIVP_EXT_IF_ST_WAITING_LC_PORT_CONFIG] Triggered event: [NPIVP_EXT_IF_EV_LCP_SET_PORT_CFG_RESPONSE_SUCCESSFUL] Next state: [FSM_ST_NO_CHANGE] 491) FSM: Transition at 653380 usecs after Wed Nov 17 20:57:36 2021 Previous state: [NPIVP_EXT_IF_ST_WAITING_LC_PORT_CONFIG] Triggered event: [NPIVP_EXT_IF_EV_VIRT_FABRIC_NOT_ENABLED] Next state: [NPIVP_EXT_IF_ST_WAITING_FCID_ADDITION] 492) FSM: Transition at 654834 usecs after Wed Nov 17 20:57:36 2021 Previous state: [NPIVP_EXT_IF_ST_WAITING_FCID_ADDITION] Triggered event: [NPIVP_EXT_IF_EV_FC_ADD_RESPONSE_SUCCESSFUL] Next state: [NPIVP_EXT_IF_ST_WAITING_NS_REGISTRATION] <<<< Waiting for MDS FCNS response 493) FSM: Transition at 662513 usecs after Wed Nov 17 20:57:56 2021 Previous state: [NPIVP_EXT_IF_ST_WAITING_NS_REGISTRATION] <<<< Waiting for MDS FCNS response Triggered event: [NPIVP_EXT_IF_EV_BUSY_TIMEOUT] <<<< 20 second Timeout - resend Next state: [FSM_ST_NO_CHANGE] 494) FSM: Transition at 662524 usecs after Wed Nov 17 20:57:56 2021 Previous state: [NPIVP_EXT_IF_ST_WAITING_NS_REGISTRATION] <<<< Waiting for MDS FCNS response Triggered event: [NPIVP_EXT_IF_EV_BUSY_TIMEOUT_RETRY] <<<< Timeout - resend Next state: [FSM_ST_NO_CHANGE] 495) FSM: Transition at 670489 usecs after Wed Nov 17 20:58:16 2021 Previous state: [NPIVP_EXT_IF_ST_WAITING_NS_REGISTRATION] <<<< Waiting for MDS FCNS response Triggered event: [NPIVP_EXT_IF_EV_BUSY_TIMEOUT] <<<< 20 second Timeout - resend Next state: [FSM_ST_NO_CHANGE]
End devices are connected to a Nexus 9000 in NPV mode. Nexus 9000 is connected via FCOE to the upstream NPIV switch. VFC interfaces are bound to a port-channel. The port-channel bound to the VFC has down links.
There are two possible workarounds: Remove the VFC bindings and apply them to the physical links. or Remove the down links from the port channel. End devices may need to be reloaded to re-initialize the login process
n/a