General
bfd session failure on edge device
Symptom
BFD session may stuck down on cEdge device under certain conditions.
SA ID for affected session is zero under "show platform software sdwan session" command.
IPSec encap/decap is growing for respective IPSec.
Conditions
Typically by use of command "clear sdwan omp all" on cEdge device.
Sometimes as racing conditions between IPSec / bfd session refresh info.
Workaround
When it happens, issue command "clear sdwan control connections" from the same cedge would bring back the BFD sessions that are down.
Further Problem Description