8812 sends cefcModuleStatusChange traps for interfaces where the 400GE transceivers were present and the interfaces were admin-down
LC reseat
NA
Check a LC has a 400G optic or 40G Optic inserted. In below scenario, LC has 400G optic in 0/0/0/0 & 0/0/0/35 respectively. RP/0/RP0/CPU0:rnh8-r-201#show inv | inc "FourHundredGigE" Mon Sep 13 17:08:03.816 AEST NAME: "FourHundredGigE0/0/0/0", DESCR: "Cisco QSFPDD 400G LR8 Pluggable Optics Module" NAME: "FourHundredGigE0/1/0/0", DESCR: "Cisco QSFPDD 400G LR8 Pluggable Optics Module" NAME: "FourHundredGigE0/2/0/0", DESCR: "Cisco QSFPDD 400G LR8 Pluggable Optics Module" RP/0/RP0/CPU0:rnh8-r-201#show inv | inc "FortyGigE" Mon Sep 13 17:09:32.328 AEST NAME: "FortyGigE0/0/0/35", DESCR: "Cisco QSFP+ 40G 4x10G BASE LR Pluggable Optics Module" Shutdown the LC. RP/0/RP0/CPU0:rnh8-r-201#shutdown location 0/0/CPU0 Mon Sep 13 17:16:33.862 AEST Proceed with shutdown? [confirm] Router sends following 3 x SNMP traps about CefcModuleStateChange, Each for a LC, 400G Optic and 40G Optic RP/0/RP1/CPU0:Sep 13 17:16:35.296 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 3; last change time = 215374189, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP0/CPU0:Sep 13 17:16:35.296 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 3; last change time = 215374189, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP0/CPU0:Sep 13 17:16:35.325 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 2457601; module operation status = 3; last change time = 0, physical entity description = Cisco QSFPDD 400G LR8 Pluggable Optics Module, physical entity name = FourHundredGigE0/0/0/0 RP/0/RP1/CPU0:Sep 13 17:16:35.325 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 2457601; module operation status = 3; last change time = 0, physical entity description = Cisco QSFPDD 400G LR8 Pluggable Optics Module, physical entity name = FourHundredGigE0/0/0/0 RP/0/RP0/CPU0:Sep 13 17:16:35.346 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 2600961; module operation status = 3; last change time = 6780389, physical entity description = Cisco QSFP+ 40G 4x10G BASE LR Pluggable Optics Module, physical entity name = FortyGigE0/0/0/35 RP/0/RP1/CPU0:Sep 13 17:16:35.345 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 2600961; module operation status = 3; last change time = 6780389, physical entity description = Cisco QSFP+ 40G 4x10G BASE LR Pluggable Optics Module, physical entity name = FortyGigE0/0/0/35 RP/0/RP0/CPU0:Sep 13 17:17:16.118 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 15; last change time = 215378289, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP1/CPU0:Sep 13 17:17:16.118 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 15; last change time = 215378289, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 FirstOccurrence Node Summary 13 Sep 2021, 17:17:16 rnh8-r-201 Module Status : Powered Down ( 15 ), Descr: Cisco 8800 36x400GE QSFP56-DD Line Card, Name: 0/0/CPU0 13 Sep 2021, 17:16:36 rnh8-r-201 Module Status : Administratively Disabled ( 3 ), Descr: Cisco QSFP+ 40G 4x10G BASE LR Pluggable Optics Module, Name: FortyGigE0/0/0/35 13 Sep 2021, 17:16:35 rnh8-r-201 Module Status : Administratively Disabled ( 3 ), Descr: Cisco QSFPDD 400G LR8 Pluggable Optics Module, Name: FourHundredGigE0/0/0/0 Reload the LC to bring it up. RP/0/RP0/CPU0:rnh8-r-201#reload location 0/0/CPU0 Mon Sep 13 17:26:42.329 AEST Proceed with reload? [confirm] Router only send LC power up/OK trap but doesn’t send Optics power up/OK traps and that’s the problem. RP/0/RP1/CPU0:Sep 13 17:26:43.375 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 3; last change time = 215434989, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP0/CPU0:Sep 13 17:26:43.376 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 3; last change time = 215434989, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP1/CPU0:Sep 13 17:26:44.385 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 15; last change time = 215435089, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP0/CPU0:Sep 13 17:26:44.385 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 15; last change time = 215435089, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP0/CPU0:Sep 13 17:26:44.527 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 16; last change time = 215435089, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP1/CPU0:Sep 13 17:26:44.527 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 16; last change time = 215435089, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP0/CPU0:Sep 13 17:27:42.691 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 5; last change time = 215440889, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP1/CPU0:Sep 13 17:27:42.691 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 5; last change time = 215440889, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP0/CPU0:Sep 13 17:30:06.044 AEST: mibd_entity[232]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 2; last change time = 215455289, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 RP/0/RP1/CPU0:Sep 13 17:30:06.049 AEST: mibd_entity[278]: frucontrolmib_cardstatus_notify: TRAP: cefcModuleStatusChange physical entity index = 1; module operation status = 2; last change time = 215455289, physical entity description = Cisco 8800 36x400GE QSFP56-DD Line Card, physical entity name = 0/0/CPU0 LastOccurrence Node Summary 13 Sep 2021, 17:30:08 rnh8-r-201 Module Status : OK ( 2 ), Descr: Cisco 8800 36x400GE QSFP56-DD Line Card, Name: 0/0/CPU0 13 Sep 2021, 17:27:42 rnh8-r-201 Module Status : Booting ( 5 ), Descr: Cisco 8800 36x400GE QSFP56-DD Line Card, Name: 0/0/CPU0 Oper type values for cefcModuleOperStatus Trap: Object cefcModuleOperStatus OID 1.3.6.1.4.1.9.9.117.1.2.1.1.2 Type ModuleOperType 1:unknown 2:ok 3:disabled 4:okButDiagFailed 5:boot 6:selfTest 7:failed 8:missing 9:mismatchWithParent 10:mismatchConfig 11:diagFailed 12:dormant 13:outOfServiceAdmin 14:outOfServiceEnvTemp 15:poweredDown 16:poweredUp 17:powerDenied 18:powerCycled 19:okButPowerOverWarning 20:okButPowerOverCritical 21:syncInProgress 22:upgrading 23:okButAuthFailed 24:mdr 25:fwMismatchFound 26:fwDownloadSuccess 27:fwDownloadFailure