Symptom
traceback and then fib_mgr crash
LC/0/4/CPU0:Sep 8 11:57:41.335 EDT: fib_mgr[184]: %ROUTING-FIB-3-ASSERT_RL : FIB internal inconsistency detected: leaf nh ext 180 >> : pkg/bin/fib_mgr : (PID=64622703) : -Traceback= 4bc829ec 4cd0e6c4 4bc83158 4028246c 4007aac4 40090fb8 400618b8 4019bf5c 401ace4c 401a4bac 4005eb10 40018404 4001adc8 401c2ed4 4003c95c 4003d128
LC/0/4/CPU0:Sep 8 11:57:41.337 EDT: fib_mgr[184]: %ROUTING-FIB-3-ASSERT : FIB internal inconsistency detected: leaf 1581 failed to link leaf to nhinfo >> : pkg/bin/fib_mgr : (PID=64622703) : -Traceback= 4bc829ec 4cd0e634 4cd0e780 4007ac30 40090fb8 400618b8 4019bf5c 401ace4c 401a4bac 4005eb10 40018404 4001adc8 401c2ed4 4003c95c 4003d128 4003ddc4
Conditions
VRRP IPv6 configuration and ipv6 ND DAD is disabled on BVI interface.
BVI interface flap.
It is a day one issue and affects all IOS-XR platforms
Workaround
Enabling ipv6 ND DAD should reduce the chance of the crash.
Further Problem Description