Symptom
SAGetStatus-platform_smart_lic_retrieve_chassis_info():247, Failed to get chassis info from sysDB rc=1082230272('sysdb' detected the 'warning' condition 'A SysDB client tried to access a nonexistent i
Conditions
"8101-32FH":
RP/0/RP0/CPU0:pp-fix-r1-pod11#sh lic plat summary
Tue Aug 3 07:31:54.338 UTC
Collection: LAST: Tue Aug 03 2021 07:04:16 UTC
NEXT: Tue Aug 03 2021 08:04:16 UTC
Reporting: LAST: Tue Aug 03 2021 06:04:16 UTC
NEXT: Wed Aug 04 2021 06:04:16 UTC
**********************************IMPORTANT************************************
SIA Status: Out of Compliance(Grace Period Expired)
SW Upgrades are blocked as SIA grace period has expired
*******************************************************************************
Count
Feature/Area Entitlement Last Next
============ =================================================== ==== ====
FCM 8102-64H Base Hardware Tracking PID 1 1
FCM Core & Aggr Essentials SW Right-to-Use per 100G for 6 6
FCM Core & Aggr Essentials SIA per 100G for Cisco 8000 6 6
RP/0/RP0/CPU0:pp-fix-r1-pod11#
RP/0/RP0/CPU0:pp-fix-r1-pod11#sh lic udi
Tue Aug 3 07:31:58.416 UTC
RP/0/RP0/CPU0:pp-fix-r1-pod11#
RP/0/RP0/CPU0:pp-fix-r1-pod11#sh platform
Tue Aug 3 07:33:58.283 UTC
Node Type State Config state
--------------------------------------------------------------------------------
0/RP0/CPU0 8102-64H(Active) IOS XR RUN NSHUT
0/PM0 PSU650W-ACPI OPERATIONAL NSHUT
0/PM1 PSU650W-ACPI OPERATIONAL NSHUT
0/FT0 FAN-2RU-PI-V2 OPERATIONAL NSHUT
0/FT1 FAN-2RU-PI-V2 OPERATIONAL NSHUT
0/FT2 FAN-2RU-PI-V2 OPERATIONAL NSHUT
RP/0/RP0/CPU0:pp-fix-r1-pod11#
RP/0/RP0/CPU0:pp-fix-r1-pod11#lice smart register idtoken Y2YxZTkyZDEtOTlhZS00MjY1LTkyMDgtNTYwYTEwY2I5MzE2LTE2NTUxOTc5%0AODQ3ODd8YXdWQ2plQVBzV1YzZ2pqZXNOd2VIN25YMzZ2aFMvT0FvczlZdlU3%0AK3U0VT0%3D%0A force
Tue Aug 3 06:41:57.144 UTC
Error: License command "license smart register idtoken " failed.
RP/0/RP0/CPU0:pp-fix-r1-pod11#