Symptom
## packets from client gets dropped by Edge and does not go out on the uplink towards Border
## happens to random VN on the edge
## packets instead of going through the hardware, gets punted to the
## Elam shows Cpu Q in the output for this traffic
Conditions
## Seen on 9300 Edge devices connecting IOT devices
## 9300 running 17.3.2a
## multiple VN's but issue happens to a particular VN
## mostly happens after a reboot/power cycle of the switch
Workaround
## Reconfigure the Lisp instance ID again
## reprovision the switch