Symptom
ASA/FTD may go into a Split Brain scenario is case the command "show conn" (or any of its variances) is run when the failover link communication is down.
Conditions
> ASA units in Failover mode on releases affected
> Communication between failover units over link down
> Failover polling interval and Holdtime are configured very short value, such as:
failover polltime unit msec 200 holdtime 1
> Execution of "show conn" command under above circumstances
Workaround
Increase the failover polling interval and Holdtime values on the failover config section.
Further Problem Description