Symptom
Navigating through Access Control Policy under one specific Domain, FMC GUI shows "Error during poilicy validation"
Error in processing getWarningsAndErrors:
com.cisco.nm.vms.common.exception.VmsException: Internal Error
at com.cisco.nm.vms.common.idmapping.IdMappingUtil.convertUUIDtoID(IdMappingUtil.java:336)
at com.cisco.nm.vms.fwsvc.policy.ngfw.validation.helpers.validator.ObjectUsageValidator.getMappedDeviceIdsFromZones(ObjectUsageValidator.java:533)
at com.cisco.nm.vms.fwsvc.policy.ngfw.validation.helpers.validator.ObjectUsageValidator.populateZoneDeviceMixupsValidationMsgs(ObjectUsageValidator.java:496)
Conditions
- The issue is seen after FMC upgrade to 6.6.4.
- Access Control Policy configured under one specific Domain.
- The "sensor" table is properly in sync between MariaDB and Sybase.
Workaround
- Contact to TAC to apply workaround