Symptom
Syslog showing different Serial Number after FAN Tray OIR compare to show inventory in NCS 560.
/// Remove ///
0/RP0/ADMIN0:Apr 1 11:22:12.921 UTC: shelf_mgr[3701]: %INFRA-SHELF_MGR-5-CARD_REMOVAL : Location: 0/FT0, Serial#: FOC1234N12A
/// Insert ///
0/RP0/ADMIN0:Apr 1 11:22:59.851 UTC: shelf_mgr[3701]: %INFRA-SHELF_MGR-5-CARD_INSERTION : Location: 0/FT0, Serial #: FOC1234N12A
/// show inventory ///
NAME: "0/FT0", DESCR: "Cisco NCS 560-4 High Speed Power Fan - Industrial Temperature "
PID: N560-4-PWR-FAN , VID: V01 , SN: FOC1235N1K0
/// show diag ///
0/FT0-IDPROM - Cisco NCS 560-4 High Speed Power Fan - Industrial Temperature
Info
PCA Number : 73-19459-02
PCB Serial Number : FOC1234N12A
Top Assy. Part Number : 068-6750-01
Top Assy. Revision : A0
Chassis Serial Number : FOC1235N1K0
CLEI Code : INCPADTCAA
ECI Number : 1A2908
PID : N560-4-PWR-FAN
Version Identifier : V01
Conditions
When inserting or removing the FAN Tray
Further Problem Description
"show inventory" command showing "Chassis Serial Number" but syslog showing "PCB Serial Number".
"show diag" command can be check the Serial Number of both the "PCB" and the "Chassis"