Symptom
Internal PXE of LC failing due to Timeout waiting for image installation to complete
Conditions
1. Executing iPXE from sysadmin:
hw-module location bootmedia network reload
2. For all nodes in the system
3. Sometimes will trigger failure
4. observed on fully loaded 8 slot or 16 slot chassis
Workaround
LC automatically recovers by doing an extra reload
Further Problem Description
Syslogs from console when issue happens:
0/RP0/ADMIN0:Mar 26 21:18:57.557 IST: cm[3468]: %ROUTING-TOPO-5-OIR_ACTION : Card sw failure having serial number: JAE204301ZB.
0/RP0/ADMIN0:Mar 26 21:18:57.557 IST: shelf_mgr[3512]: %INFRA-SHELF_MGR-6-SW_EVENT : Rcvd SW event SW_EVENT_FAILURE, event_reason_str 'Timeout waiting for image installation to complete' for card 0/2
0/RP0/ADMIN0:Mar 26 21:18:57.557 IST: shelf_mgr[3512]: %INFRA-SHELF_MGR-3-SW_FAILURE_EVENT : SW failure event SW_EVENT_FAILURE, event_reason_str 'Timeout waiting for image installation to complete' for card 0/2
0/RP0/ADMIN0:Mar 26 21:18:57.557 IST: shelf_mgr[3512]: %INFRA-SHELF_MGR-3-CARD_SW_FAILED : Card: 0/2 software state going to FAILED