Symptom
Micron 5100 SSD firmware upgrade to D0MU075
Conditions
RSP4-LT: A9K-RSP880-LT-SE / TR
Further Problem Description
Micron 5100 SSD firmware upgrade to D0MU075
Procedure for CXR:
After the SMU activation, the following TCL script must be run manually.
Enter shell of RSP (RSP0 in following example, replace RSP0 by RSP1 to upgrade SSD on RSP1) and change directory to '/disk0a:/usr' :
RP/0/RSP0/CPU0:ios#run attach 0/rsp0/cpu0
#cd /disk0a:/usr
Then run the upgrade script: /pkg/sbin/ssd_upgrade.tcl :
# tclsh /pkg/sbin/ssd_upgrade.tcl
20220208-07:16:02 ---------------->| Collecting sh version output|<-----------
20220208-07:16:07 ###Software Image version in box: 6.7.3
[snip]
20220208-07:17:00 ----->|Success: Upgrading /dev/hd1 to version: D0MU075 |<-----------
20220208-07:17:00 ## Upgrade of Micron SSD Completed Successfully##
20220208-07:17:00 @@@ Upgrade Success@@@
20220208-07:17:00 ##Moving the log file /tmp/20220208-071602-ssd_upgrade.log to /harddisk:/ssd-upgrade/20220208-071602-ssd_upgrade.log ##
## Deleting log as Upgrade is Successfully completed ##
Bailing out...