Symptom
N9K running ACI version 4.1(1k):
diagnostic test on module 1 14) "fabp-lb-dis:" comes back Untested "U" after reload, power-cylce, or after manually clearing results and re-running diagnostics.
fab2-spine1# show diagnostic result module 1 detail
...
14) fabp-lb-dis:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
-----------------------------------------------------
U U U U U U U U U U U U U U U U
Port 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
-----------------------------------------------------
U U U U U U U U U U U U U U U U
Error code ------------------> DIAG TEST SUCCESS
Total run count -------------> 1
Last test execution time ----> Mon Mar 1 00:01:04 2021
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> Mon Mar 1 00:01:04 2021
Total failure count ---------> 0
Consecutive failure count ---> 0
Last failure reason ---------> No failures yet
Next Execution time ---------> n/a
______________________________________________________________________
Conditions
N9K C9504 running ACI version 4.1(1k)
fab2-spine1# cat /tmp/stateless_boot
stateless
Further Problem Description
Workarounds provided in CSCuy02211 applied and "module 1 test 14) fabp-lb-dis" still comes back Untested.