Symptom
eXR:Temperature and Voltage values of MPA is Zero or Missing (an exclamation mark is shown as well)
P/0/RP0/CPU0:router#admin sh env temp
Fri Feb 26 11:11:49.518 CET
================================================================================
Location TEMPERATURE Value Crit Major Minor Minor Major Crit
Sensor (deg C) (Lo) (Lo) (Lo) (Hi) (Hi) (Hi)
--------------------------------------------------------------------------------
--- skipped
0/8/0
Inlet 39 -10 -5 0 60 65 75
Hotspot 48 -10 -5 0 90 93 95
DIE_PHY0 - -10 -5 0 113 122 137
0/8/1
! Inlet 0 -10 -5 0 60 65 75 <--------
! Hotspot 0 -10 -5 0 90 93 95
DIE_PHY0 - -10 -5 0 113 122 137
--- skipped
Conditions
The issue is seen in eXR 6.2.3 equipped with A9K-MPA-20X10GE on A9K-MOD400-SE
Further Problem Description
the voltage sensor can be affected as well
RP/0/RP0/CPU0:router#admin sh env temp
Fri Feb 26 11:03:22.227 CET
================================================================================
Location TEMPERATURE Value Crit Major Minor Minor Major Crit
Sensor (deg C) (Lo) (Lo) (Lo) (Hi) (Hi) (Hi)
--------------------------------------------------------------------------------
--- skipped
0/8/1
! VP5P0 0 4000 4040 5544 5600
! VP7P0 0 5581 5637 7762 7840
! VP0P9 0 720 727 998 1008
! VP1P2 0 960 970 1331 1344
! VP1P8 0 1440 1454 1996 2016
! VP2P5 0 2000 2020 2772 2800
! VP1P5 0 1200 1212 1663 1680
! VP3P3 0 2640 2666 3659 3696
! VP1P0 0 800 808 1109 1120
! VP3P3_LD0 0 2640 2666 3659 3696
! VP0P96_ANA 0 768 776 1026 1036
! IBV_PSEQ 0 7800 7956 11415 11648
--- skipped