Symptom
Catalyst 9400 LiteOn Power Supply in Standby Slot goes in faulty state
Switch#show inventory
NAME: "Power Supply Module 4", DESCR: "Cisco Catalyst 9400 Series 3200W AC Power Supply"
PID: C9400-PWR-3200AC , VID: V01 , SN: LIT########
If serial number starts with "LIT" , then its a LiteOn power supply. Other power supplies are not affected by it.
Switch#show power detail
Power Fan States
Supply Model No Type Capacity Status 1 2
------ -------------------- ---- -------- ------------ -----------
PS1 C9400-PWR-3200AC ac 3200 W active good good
PS2 C9400-PWR-3200AC ac 3200 W active good good
PS3 C9400-PWR-3200AC ac 3200 W active good good
PS4 C9400-PWR-3200AC ac 3200 W active good good
PS5 C9400-PWR-3200AC ac 3200 W active good good
PS8 C9400-PWR-3200AC ac n.a. faulty good good
PS Current Configuration Mode : N+1 redundant
PS Current Operating State : Combined
PS Slots Configured standby : PS8
Conditions
Have a PSU inserted in a standby slot in a Cat9400 and wait for a couple of hours.
Workaround
Operate Power supply in combined power budget mode: 'power redundancy-mode combined'
Further Problem Description
This is a software issue not caused by faulty hardware.
This bug is specific to 16.9.x and 16.12.x.