Symptom
The upgrade process from 16.12.4 to 17.3.2 takes several hours when using a large configuration. The router will not be accessible during this time. The upgrade process will complete successfully but will take several hours to complete
Conditions
Upgrade from 16.12.4 to 17.3.2
Workaround
Use a smaller staging configuration when doing the upgrade. Upgrade the router to 17.2.3 code. Push the operational configuration when upgrade complete
Further Problem Description
The router will hang at the below point and will be un-responsive for a long period of time
All TCP AO KDF Tests Pass
cisco ASR1001-X (1NG) processor (revision 1NG) with 3756911K/6147K bytes of memory.
Processor board ID FXS1946Q44M
Router operating mode: Controller-Managed
6 Gigabit Ethernet interfaces
2 Ten Gigabit Ethernet interfaces
32768K bytes of non-volatile configuration memory.
8388608K bytes of physical memory.
6594559K bytes of eUSB flash at bootflash:.
{The "Press RETURN to get started!" will not appear}