slices are configured via native hw-module CLI, when config (slice config and hold-off time) is pushed via OC then it was observed that hold-off timer gets configured.
When user passes config via OC and slices are already configured via hw-module CLI.
NA
Steps: 1.slice 2: hw-module location 0/RP0/CPU0 slice 2 client bitrate 100G trunk bitrate 250G fec SoftDecision20 2. before pushing the config RP/0/RP0/CPU0:NCS1K-SIT-TB2#show controllers hundredGigECtrlr 0/0/0/15 Fri Oct 23 15:41:02.310 IST Operational data for interface HundredGigECtrlr0/0/0/15: State: Administrative state: enabled Operational state: Up LED state: Green On Maintenance: Disabled AINS Soak: None Total Duration: 0 hour(s) 0 minute(s) Remaining Duration: 0 hour(s) 0 minute(s) 0 second(s) Laser Squelch: Enabled Phy: Media type: Not known Statistics: FEC: Corrected Codeword Count: 0 Uncorrected Codeword Count: 2957 Autonegotiation disabled. Operational values: Speed: 100Gbps Duplex: Full Duplex Flowcontrol: None Loopback: None (or external) BER monitoring: Not supported Forward error correction: Standard (Reed-Solomon) Holdoff Time: 0ms 3. pushed the Hold-off time config from OC 4. After pushing the config error shown in oc Enabled TLS for Router Application Client emsMergeConfig: Received ReqId 50099, Response ' { "cisco-grpc:errors": { "error": [ { "error-type": "application", "error-tag": "operation-failed", "error-severity": "error", "error-path": "Cisco-IOS-XR-terminal-device-cfg:optical-channels/optical-channel[ifname = '0_0-OpticalChannel0_0_0_20']/operational-mode", "error-message": "Provisioning Failed: Internal Error. Controller create failed for slice: 2. CLI to terminal device yang model transition disabled. Slice is already configured through different configuration." } ] } } 5. output on the node RP/0/RP0/CPU0:NCS1K-SIT-TB2#show controllers hundredGigECtrlr 0/0/0/15 Fri Oct 23 16:19:20.702 IST Operational data for interface HundredGigECtrlr0/0/0/15: State: Administrative state: enabled Operational state: Up LED state: Green On Maintenance: Disabled AINS Soak: None Total Duration: 0 hour(s) 0 minute(s) Remaining Duration: 0 hour(s) 0 minute(s) 0 second(s) Laser Squelch: Enabled Phy: Media type: Not known Statistics: FEC: Corrected Codeword Count: 0 Uncorrected Codeword Count: 2957 Autonegotiation disabled. Operational values: Speed: 100Gbps Duplex: Full Duplex Flowcontrol: None Loopback: None (or external) BER monitoring: Not supported Forward error correction: Standard (Reed-Solomon) Holdoff Time: 20ms Expected behavior: should not change the hold-off timer