10G interface on NCS560 on PID A900-IMA8CS1Z-M flapped more than 1 time upon LC OIR / Reload action. RP/0/RP0/CPU0:Turin#sh logging | i 0/0/0/22 LC/0/0/CPU0:Oct 12 12:29:59.422 UTC: fia_driver[296]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/0/0/22, Detected Local Fault LC/0/0/CPU0:Oct 12 12:29:59.423 UTC: ifmgr[311]: %PKT_INFRA-LINK-3-UPDOWN : Interface TenGigE0/0/0/22, changed state to Down LC/0/0/CPU0:Oct 12 12:29:59.423 UTC: ifmgr[311]: %PKT_INFRA-LINEPROTO-5-UPDOWN : Line protocol on Interface TenGigE0/0/0/22, changed state to Down LC/0/0/CPU0:Oct 12 12:30:08.937 UTC: optics_driver[162]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :OPTICS RX LOS LANE-0 :DECLARE :0/0/CPU0: Optics0/0/0/22 LC/0/0/CPU0:Oct 12 12:30:08.937 UTC: optics_driver[162]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :OPTICS RX POWER LANE-0 LOW ALARM :DECLARE :0/0/CPU0: Optics0/0/0/22 LC/0/0/CPU0:Oct 12 12:33:56.305 UTC: fia_driver[296]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/0/0/22, Detected Local Fault MSG LC/0/0/CPU0:Oct 12 12:33:56.313 UTC: fia_driver[296]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/0/0/22, Detected Local Fault LC/0/0/CPU0:Oct 12 12:33:56.589 UTC: fia_driver[296]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/0/0/22, Detected Local Fault MSG LC/0/0/CPU0:Oct 12 12:33:56.618 UTC: ifmgr[311]: %PKT_INFRA-LINK-3-UPDOWN : Interface TenGigE0/0/0/22, changed state to Up LC/0/0/CPU0:Oct 12 12:33:56.618 UTC: ifmgr[311]: %PKT_INFRA-LINEPROTO-5-UPDOWN : Line protocol on Interface TenGigE0/0/0/22, changed state to Up LC/0/0/CPU0:Oct 12 12:33:57.981 UTC: fia_driver[296]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/0/0/22, Detected Local Fault LC/0/0/CPU0:Oct 12 12:33:57.982 UTC: ifmgr[311]: %PKT_INFRA-LINK-3-UPDOWN : Interface TenGigE0/0/0/22, changed state to Down LC/0/0/CPU0:Oct 12 12:33:57.982 UTC: ifmgr[311]: %PKT_INFRA-LINEPROTO-5-UPDOWN : Line protocol on Interface TenGigE0/0/0/22, changed state to Down LC/0/0/CPU0:Oct 12 12:33:57.993 UTC: fia_driver[296]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/0/0/22, Detected Local Fault MSG LC/0/0/CPU0:Oct 12 12:33:58.022 UTC: ifmgr[311]: %PKT_INFRA-LINK-3-UPDOWN : Interface TenGigE0/0/0/22, changed state to Up LC/0/0/CPU0:Oct 12 12:33:58.023 UTC: ifmgr[311]: %PKT_INFRA-LINEPROTO-5-UPDOWN : Line protocol on Interface TenGigE0/0/0/22, changed state to Up LC/0/0/CPU0:Oct 12 12:34:10.607 UTC: optics_driver[162]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :OPTICS RX LOS LANE-0 :CLEAR :0/0/CPU0: Optics0/0/0/22 LC/0/0/CPU0:Oct 12 12:34:10.607 UTC: optics_driver[162]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :OPTICS RX POWER LANE-0 LOW ALARM :CLEAR :0/0/CPU0: Optics0/0/0/22
IM Reload on 560 hw-module location reload
Moved the tx disable {laser no} after the EDC GT reset is done.
None