Symptom
LACP could err-disable port ("Internal-Fail errDisable") upon receiving unexpected LACP state change from partner.
Conditions
Partner makes an unexpected LACP state change during initialization of the interface.
Workaround
Bounce affected interface to reinitiate LACP process.
Further Problem Description
Following logs may be observed:
2010 Dec 24 21:09:15.995 SWITCH_NAME %ETH_PORT_CHANNEL-3-PCM_HWCFG_FAIL_ERROR: Port-channel:port-channel105 mbr:Ethernet1/5 SAP 347 returned error fsm processed a disruptive event for opc MTS_OPC_PCM_RX_HW_ENABLED; if lacp port-channel please collect or please collect <show t
2010 Dec 24 21:09:15.996 SWITCH_NAME %ETHPORT-5-IF_SEQ_ERROR: Error ("fsm processed a disruptive event") communicating with MTS_SAP_ETH_PORT_CHANNEL_MGR for opcode MTS_OPC_ETHPM_BUNDLE_MEMBER_BRINGUP (RID_PORT: Ethernet1/5)
2010 Dec 24 21:09:16.004 SWITCH_NAME %ETH_PORT_CHANNEL-5-PORT_DOWN: port-channel105: Ethernet1/5 is down
2010 Dec 24 21:09:16.024 SWITCH_NAME %ETH_PORT_CHANNEL-5-FOP_CHANGED: port-channel105: first operational port changed from Ethernet1/5 to none
2010 Dec 24 21:09:16.200 SWITCH_NAME %ETHPORT-5-IF_DOWN_ERROR_DISABLED: Interface Ethernet1/5 (description:) is down (Error disabled. Reason:fsm processed a disruptive event)