Symptom
DS3_ADMIN_DOWN alarm persists after no shut of the controller
R1#sh facility-alarm status | sec 0/4/0
T3 0/4/0 Mar 30 2020 22:24:10 CRITICAL DS3_RX_LOS Receiver has loss of signal [3]
T3 0/4/0 Mar 30 2020 22:24:10 CRITICAL DS3_LINK_DOWN Ds3 Port Link Down [9]
R1#sh facility-alarm status | sec 0/11/0
T3 0/11/0 Mar 30 2020 22:24:10 CRITICAL DS3_RX_LOS Receiver has loss of signal [3]
T3 0/11/0 Mar 30 2020 22:24:10 CRITICAL DS3_LINK_DOWN Ds3 Port Link Down [9]
R1#
R1#conf t
Enter configuration commands, one per line. End with CNTL/Z.
R1(config)#controller t3 8/0/0
R1(config-controller)#shut
R1(config-controller)#do sh facility-alarm status | sec 0/4/0
T3 0/4/0 Mar 30 2020 22:27:23 INFO DS3_ADMIN_DOWN Ds3 Port Admin Down [10]
R1(config-controller)#do sh facility-alarm status | sec 0/11/0
T3 0/11/0 Mar 30 2020 22:27:23 INFO DS3_ADMIN_DOWN Ds3 Port Admin Down [10]
R1(config-controller)#no shut
R1(config-controller)#do sh facility-alarm status | sec 0/4/0
T3 0/4/0 Mar 30 2020 22:27:23 INFO DS3_ADMIN_DOWN Ds3 Port Admin Down [10]
R1(config-controller)#do sh facility-alarm status | sec 0/11/0
T3 0/11/0 Mar 30 2020 22:27:23 INFO DS3_ADMIN_DOWN Ds3 Port Admin Down [10]
Conditions
NCS42xx
Two cards NCS4200-48T3E3-CE set up with card-protection
T3 controller mode
Shut/no shut of one controller
T3 controller operates correctly in shut/no shut config.
Workaround
If ports are connected, the false alarm will be cleared
Further Problem Description