Symptom
A vulnerability in the web services interface of Cisco Adaptive Security Appliance (ASA) and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to upload arbitrary-sized files to specific folders on an affected device, which could lead to an unexpected device reload.
The vulnerability exists because the affected software does not efficiently handle the writing of large files to specific folders on the local file system. An attacker could exploit this vulnerability by uploading files to those specific folders. A successful exploit could allow the attacker to write a file that triggers a watchdog timeout, which would cause the device to unexpectedly reload, causing a denial of service (DoS) condition.
Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.
This advisory is available at the following link:
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-asaftd-fileup-dos-zvC7wtys
Conditions
Please refer to the Security Advisory.
Workaround
Please refer to the Security Advisory.
Further Problem Description
Please refer to the Security Advisory.
PSIRT Evaluation
The Cisco PSIRT has assigned this bug the following CVSS version 3 score. The Base CVSS score as of the time of evaluation is 8.6:
https://tools.cisco.com/security/center/cvssCalculator.x?vector=CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
CVE ID CVE-2020-3436 has been assigned to document this issue.
Additional information on Cisco's security vulnerability policy can be found at the following URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html