Symptom
After copying NCS5k ISO image to harddisk, creating image reference. Image reference shows up fine on that RSP.
1. After creating image reference in host, another RSP is not having any clue of the image reference created, after RSP switchover. image reference is not created fine.
2. continuous icpe_satmgr crashes are seen.
3. satellites are completely down, as crash is seen. cli - show nv satellite status - shows nothing.
Conditions
image reference is created in one RSP. and do RSP Switchover and check image reference created.
Workaround
trigger upgrade on-connect on the same RSP, where you created image reference.
Further Problem Description
we do this procedure. After copying NCS5k ISO image to harddisk, creating image reference. Image reference shows up fine on that RSP.
1. After creating image reference in host, another RSP is not having any clue of the image reference created, after RSP switchover. image reference is not created fine.
2. continuous icpe_satmgr crashes are seen.