Symptom
When either Active or standby A9K-RSP440-TR is removed from the Chassis ,the output for "show platform" still shows the RSP present in the chassis. Removal of Active RSP can make system to run into inconsistency state.
Conditions
When any one of the RSP is removed fro the chassis
Workaround
Limitations in RSP A9K-RSP440-TR makes OIR a not supported mode of operation.
Recommended procedure, first execute switchover, then remove module when working as Standby RSP.
Further Problem Description
When either Active or standby A9K-RSP440-TR is removed from the Chassis ,the output for "show platform" still shows the RSP present in the chassis.
SDR Inventory
--------------
Type NodeName NodeState RedState PartnerName
---------------------------------------------------------------
RP 0/RSP0/CPU0 IOS XR RUN Primary NONE
RP 0/RSP1/CPU0 NOT_PRESENT Not-known NONE >>>>>>> RSP1 is removed
LC 0/0/CPU0 IOS XR RUN Not-known NONE
LC 0/1/CPU0 IOS XR RUN Not-known NONE
LC 0/2/CPU0 IOS XR RUN Not-known NONE
LC 0/3/CPU0 IOS XR RUN Not-known NONE
LC 0/4/CPU0 IOS XR RUN Not-known NONE
LC 0/5/CPU0 IOS XR RUN Not-known NONE
LC 0/6/CPU0 IOS XR RUN Not-known NONE
+++++++++++ admin show platform [17:17:52.258 MST Thu Jan 09 2020] ++++++++++++
Node Type State Config State
-----------------------------------------------------------------------------
0/RSP0/CPU0 A9K-RSP440-TR(Standby) IOS XR RUN PWR,NSHUT,MON
0/RSP1/CPU0 A9K-RSP440-TR(Active) IOS XR RUN PWR,NSHUT,MON >>> RSP1 still shown in the output
0/FT0/SP ASR-9010-FAN-V2 READY
0/FT1/SP ASR-9010-FAN-V2 READY
0/0/CPU0 A9K-48X10GE-1G-TR IOS XR RUN PWR,NSHUT,MON
0/1/CPU0 A9K-48X10GE-1G-TR IOS XR RUN PWR,NSHUT,MON
0/2/CPU0 A9K-48X10GE-1G-TR IOS XR RUN PWR,NSHUT,MON
0/3/CPU0 A9K-48X10GE-1G-TR IOS XR RUN PWR,NSHUT,MON
0/4/CPU0 A9K-48X10GE-1G-TR IOS XR RUN PWR,NSHUT,MON
0/5/CPU0 A9K-48X10GE-1G-TR IOS XR RUN PWR,NSHUT,MON
0/6/CPU0 A9K-48X10GE-1G-TR IOS XR RUN PWR,NSHUT,MON
0/PS0/M0/SP PWR-2KW-DC-V2 READY PWR,NSHUT,MON
0/PS0/M1/SP PWR-2KW-DC-V2 READY PWR,NSHUT,MON
0/PS0/M2/SP PWR-2KW-DC-V2 READY PWR,NSHUT,MON
0/PS1/M0/SP PWR-2KW-DC-V2 READY PWR,NSHUT,MON
0/PS1/M1/SP PWR-2KW-DC-V2 READY PWR,NSHUT,MON
0/PS1/M2/SP PWR-2KW-DC-V2 READY PWR,NSHUT,MON