Symptom
FPR-1010 appliances (running ASA software) operating constantly at a fairly high CPU temperature around 75-76 C. Since it appears that 76 C is the threshold for "Warm" rather than "OK" temperature, we are getting repeated log messages like:
%ASA-4-735015: CPU 0: Temp: 76 C, Warm
%ASA-1-735020: CPU 0: Temp: 75 C, OK
as the appliance bounces back and forth between 75 and 76 C.
firepower-1010(local-mgmt)#show env tech
*************** Chassis Temps ***************
Inlet temperature is 54 degrees Celsius
*************** CPU Data ***************
Core Temperature 0 is 74 degrees Celsius
Core Temperature 1 is 72 degrees Celsius
Core Temperature 2 is 71 degrees Celsius
Core Temperature 3 is 71 degrees Celsius
fpr1010# show cpu
CPU utilization for 5 seconds = 0%; 1 minute: 0%; 5 minutes: 0%
fpr1010# sho env temp
Temperature:
-----------------------------------
Processors:
--------------------------------
Processor 1: 74.0 C - OK (CPU Temperature)
Chassis:
--------------------------------
Ambient 1: 55.0 C - Warm (Inlet Temperature)
Conditions
FP1010 while under zero stress is running 70+ C with no obstructions around, and a ambient temp of only 55 C.
Appliance is sitting on a blank shelf in customers office. There are no obstructions on any side or above the appliances.
Further Problem Description
The "Warm" threshold for the FPR-1010 should be 85C with the critical being 100C. If the readings are less than 85, the message can be ignored.