General
N9K-C9396PX will boot into loader prompt if IPV6 address is configured on mgmt0 interface under I7.7 release. Manual boot to I7.7 with 'boot' command or boot to the previous release will ends up with following message:
Image valid
Image Signature Verification Failed.
Boot failed
Error 9: Unknown boot failure
At the same time, we are seeing a lot of hex-decimal output during the reload process before entering the loader prompt.
Symptom
The device does not boot and stops in boot-loader prompt. At same time, the reload process has some hex-decimal information.
The issue only happens in 7.0(3)I7(7) image and not applicable for any other release.
Also it is not applicable for Nexus 30xx, 3132, 3172, 3548 products
Conditions
N9K-C9396PX running under nxos.7.0.3.I7.7.bin. At same time, with IPV6 configured under mgmt0 interface.
Workaround
Unconfigure IPv6 address from the mgmt interface before upgrading to 7.0(3)I7(7)
If already configured and the issue is hit with 7.0(3)I7(7), please load older image from loader prompt -
loader > boot
Further Problem Description