Symptom
Symptoms:
+ Upgrade attempted from Cisco NX-OS Release 9.2(2) to Cisco NX-OS Release 9.3(1) using ISSU.
(Same issue seen even with cold boot)
+ Device goes into a boot loop infinitely and dumps mrib Cores
(Need to break it at loader and load 9.2.2 to recover)
+ When we remove feature PIM and perform the upgrade from Cisco NX-OS Release 9.2(2) and Cisco NX-OS Release 9.3(1), we have no issues
+ As soon as we apply feature PIM on Cisco NX-OS Release 9.3(1), device reloads with a core.
Conditions
This issue is that both MRIB and PIM need to increase in size by u4route-mem and u6route-mem, which in this case is 1.25 GB. This takes the address-space beyond the 4GB limit.
Workaround
Issue was not found to occur when u4route-mem + u6route-mem is <= 1 GB. 750MB is recommended as a safe upper limit.
Further Problem Description