Symptom
Received Local Fault is reported as Remote Fault in logs/outputs
Conditions
Local Fault is received by NCS5500 using Jericho2 chip
Further Problem Description
Outputs/logs observed when Local Fault is received
LC/0/0/CPU0:Mar 31 14:59:21.121 CEST: fia_driver[208]: %PLATFORM-DPA-2-RX_FAULT : Interface TenGigE0/0/0/0, Detected Remote Fault
LC/0/0/CPU0:Mar 31 14:59:21.122 CEST: ifmgr[243]: %PKT_INFRA-LINK-3-UPDOWN : Interface TenGigE0/0/0/0, changed state to Down
LC/0/0/CPU0:Mar 31 14:59:21.122 CEST: ifmgr[243]: %PKT_INFRA-LINEPROTO-5-UPDOWN : Line protocol on Interface TenGigE0/0/0/0, changed state to Down
RP/0/RP0/CPU0:BRU-N55A2-SE-1#show controllers tenGigE 0/0/0/0
Tue Mar 31 14:56:11.288 CEST
Operational data for interface TenGigE0/0/0/0:
State:
Administrative state: enabled
Operational state: Down (Reason: Remote fault, reason known to be far-end link loss) <<< Remote Fault
LED state: Yellow On