Symptom
Messages of Power supply faulty and Recovered from sustained overload condition might be seen on the console:
*Jul 30 17:29:27.739 PDT: %PLATFORM_FEP-1-FRU_PS_SIGNAL_FAULTY: Switch 1: signal on power supply A is faulty
*Jul 30 17:30:09.195 PDT: %PLATFORM_FEP-1-FRU_PS_SUSTAINED_OVERLOAD_RECOVERY: Switch 1: power supply
Do "show environment power all" showing the supply Overload status
Switch#show environment power all
SW PID Serial# Status Sys Pwr PoE Pwr Watts
-- ------------------ ---------- --------------- ------- ------- -----
1A PWR-C1-1100WAC LIT22102P2U Sust. Overload Bad Bad 1100
1B PWR-C1-1100WAC-P ART2226F6FH Sust. Overload Bad Bad 1100
2A PWR-C1-715WAC DCA2031G76T OK Good Good 715
2B PWR-C1-715WAC LIT22033E33 OK Good Good 715
Conditions
The messages might display on the console when:
1) After WS-C3850-12X48U-E or WS-C3850-24XU-E boot up
2) Or perform shut/no shut on a range of interfaces
Workaround
1) The supply will self-recover in few seconds when happening after boot up
2) The supply might be in loops of Faulty state and Recovered from sustained overload condition when happening after doing shut/no shut on a range of interfaces. Need to reload the switch to recover.