Symptom
Unconfiguring Unified Thread Defense (UTD) causes a traceback when unconfiguring a WAN edge
Conditions
Unconfiguring Unified Thread Defense from vmanage.
After 30 minutes the following log will be seen:
*Mar 12 07:17:00.372: %FMFP-3-OBJ_DWNLD_TO_DP_STUCK: R0/0: fman_fp_image: AOM download to Data Plane is stuck for more than 1800 seconds for obj[238] type[25] pending-issue Req-delete Issued-none 'intf VirtualPortGroup0, handle 16, hw handle 14, HW dirty: NONE AOM dirty NONE'
Workaround
Once the issue has been hit, the user must reload the router to recover the stuck object.
the issue is only seen when removing a VirtualPortGroup interface from the IOS config. A preventative workaround would be to simply put the interface in "shut" state rather than unconfiguring it, then no error will occur.
Further Problem Description
the issue is only seen when removing a VirtualPortGroup interface from the IOS config.