Symptom
A vulnerability in the Flexible NetFlow Version 9 packet processor of Cisco IOS XE Software for Cisco Catalyst 9800 Series Wireless Controllers could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device.
The vulnerability is due to improper validation of parameters in a Flexible NetFlow Version 9 record. An attacker could exploit this vulnerability by sending a malformed Flexible NetFlow Version 9 packet to the Control and Provisioning of Wireless Access Points (CAPWAP) data port of an affected device. An exploit could allow the attacker to trigger an infinite loop, resulting in a process crash that would cause a reload of the device.
Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability.
This advisory is available at the following link:
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-iosxe-fnfv9-dos-HND6Fc9u
Conditions
For information on fixed versions of software consult the Cisco IOS Software checker:
https://tools.cisco.com/security/center/softwarechecker.x
See Vulnerable Products Section of the advisory for full details:
https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-iosxe-fnfv9-dos-HND6Fc9u#vp
Workaround
There are no workarounds that address this vulnerability.
Further Problem Description
Please refer to the Security Advisory.
PSIRT Evaluation
The Cisco PSIRT has assigned this bug the following CVSS version 3 score. The Base CVSS score as of the time of evaluation is 8.6:
https://tools.cisco.com/security/center/cvssCalculator.x?version=3.0&vector=CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H
CVE ID CVE-2020-3221 has been assigned to document this issue.
Additional information on Cisco''s security vulnerability policy can be found at the following URL:
http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html