Symptom
When Cat3650 or Cat3850 or Cat9300 is configured for Flexible NetFlow [FNF] and has flow record with TCP flags as non key field [collect transport tcp flags] it will not export TCP flags properly as part of the flows.
Netflow collector will show no TCP flags.
Conditions
t3650 // Cat3850 // Cat9300
FNF flow record with "collect transport tcp flags" command
Workaround
upgrade to the fixed release
16.06.07 and later
16.09.04 and later
16.12.01 and later
Further Problem Description
this problem is affecting only the following releases:
16.06.04-16.06.06
16.09.01-16.09.03
16.10.01
16.11.01
17.xx.xx is not affected
16.03.xx is not affected